Active leaf
The door on a double door set that is the first to be opened.
Anti-crush reinforcers
Reinforcing steel-work strategically positioned to prevent crushing and to strengthen areas particularly vulnerable to attack.
Anti-lever protection
Strategic positioning of cover plates and reinforcer to prevent levering from manual attack devices.
Attack resistant
Designed to resist typical attack points made by the average intruder, using normal equipment.

Corrosion resistance
Offering resistance against corrosion. ie. electro zinc coating to protect the underlying steel.
Cylinder
a component part of a lock which accepts the key, held on by a cylinder ring secured internally by screws.
Cover plate
A reinforced strip, the length on the leading edge of the door to cover the gap between leaf and frame (or leaf and leaf on a double).

Dog Bolts
Case hardened steel dowels strategically positioned for extra security.

Electro-zinc coated
Coating used on mild steel to increase corrosion resistance.
Escape handle
Part of a panic exit system shaped as a handle where more commonly a bar would be used.
Etch Primer
Primer paint with special adhesion properties for use on coated steel.
External access
gaining entrance through a door set from the outside by means of a key or electronic device.

Fire rating
Having been tested in accordance with BS 476 part 22 1987, and given classification reflecting the resistance achieved in time.

Handing
Which side the door is hung (hinged), as viewed with the door opening towards you (see diagram below).

Inactive or Passive leaf
The door on a double door set that is the second to be opened.

Leading edge
The edge of the door leaf farthest from the hinge side.
Loss Prevention Certification Board
Part of BRE Certification Ltd. within the Foundation for the built Environment (FBE) . The LPCB operates product certification for fire and security products and services.
LPS 1175
Specification for testing and classifying the burglary resistance of building components.

Manganese Steel
A hardened steel sheet material incorporating manganese which makes it almost impossible to drill through.
Outward opening
When viewing the door from the outside the door would open towards you.

Panic bar
A device to give emergency exit from a door set by retracting it's locking mechanism when pushed.
Push pad
A rectangular shaped pad which activates a panic escape system where more commonly a bar would be used.

Security rated
Having been tested and evaluated to LPS 1175 and given a security rating by the Loss Prevention Certification Board.

Three point locking
A bolting system which secures the leaf into the frame in three places, normally top, bottom and centrally on the leading edge. Auto bolting systems include catches and triggers to automatically re-secure in these places when the door is closed, without manually resetting the device.
Two point locking
A bolting system which secures the leaf into the frame in two places, normally top and bottom on the leading edge. Auto bolting systems include catches and triggers to automatically re-secure in these places when the door is closed, without manually resetting the device.

Uncertified
A door configuration containing elements outside the scope of the certification.

Handing
Handing descriptions are as viewed with door opening towards you.
Right hand hung
Outward opening
Left hand hung
Outward opening
Left hand hung
Inward opening
Right hand hung
Inward opening
Right hand hung Left hand hung Left hand hung Right hand hung Inward opening

Home | About | Enquiries | Security Doors | Industrial Doors | Fire Doors | Flush Steel Doors | Steel Louvres | Powder Coating | Other Products | Installation Service | Contact Us

SITE MAP

Home page

About Sunray Engineering
Contact Sunray Doors
How to Find Sunray Engineering
Glossary of Terms
Security Doors Brochures
O&M Information
Company Information Pack
Accreditations
Job Opportunities at Sunray Engineering
Terms & Conditions
Security Door Enquiries
Which form to use
General Enquiries
EDF Enquiries
Have Your Say
Steel Security Doors
Overview
ExcluDoor 3 and 4
- Locking Options
- Specifications
ExecDoor Security Doors
Vision Panel
Rating Criteria
Security Door LPS 1175 Rating Criteria
Colour Charts
Industrial Steel Doors
Overview
Heavy Duty Steel Doors
- Features & Options
SaverDoor
- Technical data
LouvreDoor
- Technical data
Ventadoor - Louvred Security Door
- Technical data
- Specifications
- Standard sizes
- Locking options
FireLock
- Technical data
- Standard supply
- Dimensions
Colour Charts
Steel Fire Doors
Overview
SaverDoor Firedoor
- Technical data
FireLock Firedoor
- Technical data
- Standard supply
- Dimensions
ExcluDoor 4
Colour Charts

Flush Steel Doors
- Overview
- Technical data
- Colour charts
ExcluDoor 4
Colour Charts
Steel Louvres
Overview
Stackable louvred panel system
Louvred Panels

Powder coating

Other Products
Overview
Trench Covers
Vision Panel
KeyBox
Sunray 6000
Installation Service
Accreditation
Installation Instructions
Contact Us
Colour Charts for Steel Doors
O&M Information for Security Doors
Brochure Download
Sunray Engineering Ltd, Kingsnorth Industrial Estate, Wotton Road, Ashford, Kent TN23 6LL
T 01233 639039 F 01233 625137 E sales@sunraydoors.co.uk